| Hygienic compact temperature transmitter with high accuracy, fast response and fully welded structure for sanitary measurement tasks. |
| Model | ET-TS-0004 |
| Product Application | Suitable for temperature monitoring in hygienic pipes, tanks and heat exchangers in dairy, food and pharmaceutical processing. |
| Product Features | Precision measurement from -50 ... 250 °C Integrated 4 ... 20 mA transmitter with high accuracy Fast power-up time < 2 s All parts welded together IO-Link Dual Channel for easy commissioning In addition to the standard lengths, custom lengths up to 3000 mm are available on request |
| Process Temperature | -50~125 °C |
| Pt100 Accuracy Class (EN 60751) | 1/1 B ± (0.3 + 0.005 × t)°C |
| Max. Output Error | ≤ 0.06 % FSR @ 25 °C Including input accuracy, output accuracy and repeatability |
| Temperature Drift (By Ambient) | < 0.025 K/K + 0.01 % FSR/K |
| Thermal Response Time, T50 | RTD element and transmitter combined < 8.9 s , Ø6 mm |
| Process Pressure | 40 bar |
| Sensor Length | 50 mm/ 100 mm |
| Sensor Tube Material | AISI 316L (1.4404) |
| Surface Roughness Wetted Parts | Ra ≤ 0.8 µm |
| Degree of Protection (EN 60529) | IP68 , with appropriate cable (336 h @ 10 mH2O) IP69K , with appropriate cable |
| Humidity | ≤ 100 % RH , condensing |
| Vibration (Sinusoidal) (EN 60068-2-6) | 1.6 mm p-p (2~25 Hz), 4 g (25~100 Hz), 1 octave / min. GL, test 2 |
| Output Type | PNP NPN Digital (push-pull) 4 ... 20 mA, 2-wire 20 ... 4 mA, 2-wire |
| Switching Logic | Active high Active low |
| Voltage Drop | PNP: (+Vs - 1,2 V) ± 0.5 V, Rload ≥ 10 kΩ NPN: (-Vs + 1,5 V) ± 0.5 V, Rload ≥ 10 kΩ |
| Current Rating | 100 mA , max. |
| Off Leak Current | < 100 μA |
| Short Circuit Protection | Yes |
| EMC | EN 61326-1 |
| Safety | cULus listed, E527512 |