ET-TS-0006 Temperature Sensors

Cat No: PQSTS-LJX-0006 Datasheet

Product Name: ET-TS-0006 Temperature Sensors

Quantities: - +

Description

Front-flush mounted hygienic temperature sensor with zero dead volume, fast response and full compliance with hygienic standards.

Basic Information

Model ET-TS-0006
Product Application Used in stirred tanks, pigging systems and hygienic processes requiring easy cleaning and no residual media retention.
Product Features Optimum placement even in stirrers and pigging systems
Integrated 4 ... 20 mA transmitter or Pt100 output
Very fast response time
3-A-compliant without elastomers
Process Temperature 115~135 °C , < 1 h
-40~115 °C , permanent
Min. output span: 25 °C
Pt100 Accuracy Class (EN 60751) 1/1 B ± (0.3 + 0.005 × t)°C
1/1 A ± (0,15 + 0,002 × t)°C
1/3 B ± 1/3 × (0.3 + 0.005 × t)°C
1/6 B ± 1/6 × (0.3 + 0.005 × t)°C
Max. Conversion Error ± 0.25 °C
Max. Output Error ± 0.1 % FSR
± 0.016 mA
Temperature Drift (By Ambient) < 0.003 % FSR/°C , typ.
< 0.01 % FSR/°C , max.
Thermal Response Time, T90 ≤ 6.5 s , 20 mm
≤ 6.7 s , 50 mm
≤ 66.0 s , front-flush
Thermal Response Time, T50 ≤ 2.5 s , 20 mm.
≤ 2.7 s , 50 mm
≤ 9.0 s , front-flush
Sampling Interval 0.5 s
Sensor Length 0 mm , front-flush
20 mm
50 mm
Sensor Tube Material AISI 316L (1.4404)
Wetted Parts Material PEEK Natura
Surface Roughness Wetted Parts Ra ≤ 0.8 µm
Degree of Protection (EN 60529) IP67
IP69K , with appropriate cable
Humidity < 98 % RH , condensing
Vibration (Sinusoidal) (EN 60068-2-6) 1.6 mm p-p (2~25 Hz), 4 g (25~100 Hz), 1 octave / min.
Output Type Without transmitter: 1 x Pt100, 4-wire
With transmitter: 4~20 mA , 2-wire
Shunt resistance: Rs ≤ (Vs - 8 V)/0.023 A
Rs ≤ 680 Ohm, Vs = 24 V DC
EMC EN 61000-6-2
EN 61000-6-3
EN 61326-1
Hygiene FDA (21 CFR 177.2415)
3-A (74-07)